Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
Home Print this page Email this page
Users Online:: 17
ORIGINAL ARTICLE
Year : 2020  |  Volume : 23  |  Issue : 1  |  Page : 17-21

Reliability of transcutaneous bilirubin estimation during phototherapy in term infants: A hospital-based observational study


1 Department of Paediatrics, Vikas Hospital Pvt. Ltd, New Delhi, India
2 Department of Gastroenterology, Vikas Hospital Pvt. Ltd, New Delhi, India
3 Department of Paediatrics, Government Medical College, Srinagar, Jammu and Kashmir, India
4 Department of Accident and Emergency, Vikas Hospital Pvt. Ltd, New Delhi, India
5 School of Studies in Chemistry, Jiwaji University, Gwalior, Madhya Pradesh, India

Correspondence Address:
Dr. Jehangir Allam Bhat
Department of Paediatrics, Kurji Holy Family Hospital, Patna, Bihar
India
Login to access the Email id


DOI: 10.4103/smj.smj_11_19

Rights and Permissions

Background:Blood sampling method is the most common but invasive method for bilirubin estimation. Transcutaneous bilirubin (TCB) estimation, on the other hand is non-invasive. Objectives: The aim was to compare neonatal bilirubin estimation by serum bilirubin and transcutaneous bilirubinometer methods both pre- and during phototherapy and establish the precision of transcutaneous bilirubinometer. Materials and Methods: This prospective hospital-based observational study was conducted on 350 term neonates over a period of 2 years. Bilirubin was estimated in all newborn by both serum bilirubin and transcutaneous method, at the time of admission in nursery (prephototherapy), at 6 h after phototherapy (while neonates were still under phototherapy treatment), and at withholding phototherapy, and a photo opaque patch of 2.5 cm was used to cover the area on midforehead and transcutaneous bilirubin was estimated from this area after removing it during phototherapy. All data were tabulated and analyzed by relevant statistical tests. Results: A total of 350 term healthy newborns with mean gestational age of 38 ± 2 weeks and mean birth weight of 2.97 ± 0.9 kg were studied. Correlation analysis revealed a significant correlation between total serum bilirubin and transcutaneous method (TCB) measurements of bilirubin. When these methods were compared at pre-phototherapy, at 6 hours after phototherapy and before withholding phototherapy, correlation coefficient(r) of 0.9571, 0.7988, and 0.9206 were seen respectively. The precision levels of transcutaneous bilirubinometer (BiliCheck™) were good because plotting of Bland–Altman graphs showed maximum (>97%) data within agreement limits at all stages of phototherapy. Conclusion: Our study revealed good correlation and precision of transcutaneous bilirubinometer both before and during phototherapy. Thus, it supports the previous studies which justify the use of transcutaneous bilirubinometer in assessing newborn jaundice during phototherapy.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed547    
    Printed34    
    Emailed0    
    PDF Downloaded83    
    Comments [Add]    

Recommend this journal